Residual voltage
< 1.0VDC (load current 100mA, conductor 2m)
Leakage current
<0.01mA No-load
Current consumption
<10mA
Standard test object
45*45*1(iron)
Installation mode
Shielded type
classification
F3C / f3l-m30 universal series
Product model
F3L-30KS15-N R2M
Output mode
NPN.NO/NPN.NC PNP.NO/PNP.NC
Application scenarios
Product positioning, marking and testing
Shell material
Copper nickel plating / PBT
Connection mode
Φ 4x2m / 2-wires Φ 4x2m / 3-wires Φ 4 lead 150mm with M8 connector and M12 connector
working voltage
12 ~ 24 VDC ± 10% pulsation (P-P) less than 10%
Isolation resistance
>20m Ω (between charging part and shell)
Dielectric Strength
1000VAC 50 ~ 60Hz 1min (between charging part and shell)
temperature drift
< 10% detection distance
ambient temperature
-25℃~70℃
Output short circuit protection
Yes
Reverse connection protection of power supply
Yes
Repeatability accuracy